LAST DAY OF THE CLEARANCE SALE – FREE DELIVERY !
Sale!

R-454B Refrigerant – 20 lb Cylinder for Compatible HVAC Systems

Original price was: $328.00.Current price is: $129.00.

Low stock

79 in stock

  • Secure checkout
  • Free delivery
  • Authentic & graded
SKU: CGD-R454B-20 Categories: , Tags: , , , , Brand:

Description

R-454B Refrigerant – 20 lb Cylinder for Compatible HVAC Systems

Inventory Liquidation: This product is available at reduced clearance pricing while current inventory lasts. All applicable purchaser eligibility and verification requirements remain in effect.

Brand: Opteon™ XL41 (R-454B)   Manufacturer: The Chemours Company   MPN: D15444398   GTIN/UPC: 686114002989

20 lb R-454B cylinder for new equipment specifically designed for R-454B. A2L mildly flammable refrigerant—professional handling and purchaser verification are required.

Product Overview

R-454B is a lower-GWP A2L blend selected for compatible modern air-conditioning and heat-pump equipment.

  • Net contents: 20 lb (9.1 kg)
  • Composition: R-32 / R-1234yf
  • ASHRAE safety class A2L (mildly flammable)
  • Use only in equipment specifically approved for R-454B; not an R-410A retrofit

Safety: Follow A2L storage, transport, ventilation and service requirements. Section 608 purchaser verification applies.

Technical Specifications

Refrigerant R454B
Net Contents 20 lb (9.1 kg)
Composition R-32 (68.9%) / R-1234yf (31.1%)
Boiling Point -50.5°C
Safety Classification A2L – mildly flammable
GWP / ODP GWP 466; ODP 0

Common Applications

Main application: New HVAC and heat-pump systems specifically designed for R-454B.

Designed for new-generation residential and light-commercial air conditioners, heat pumps, packaged systems and compatible chillers built specifically for R-454B.

Compatibility Information

R-454B is an A2L blend and is not a field drop-in replacement for R-410A. The equipment, installation location, charge limits, ventilation provisions and service tools must all be approved for R-454B.

Professional Service and Charging Notes

Follow the equipment manufacturer’s A2L procedure, local mechanical and fire codes, and all ignition-control requirements. Use compatible leak detection, recovery and evacuation equipment and charge the blend in the liquid phase by specified weight.

Storage and Handling

  • Store the cylinder upright, secured and in a cool, dry, well-ventilated area.
  • Protect the cylinder from direct sunlight, excessive heat, physical damage and unauthorized access.
  • Keep the valve cap or protective collar in place during storage and transportation.
  • Use only tools, hoses, recovery equipment and personal protective equipment rated for this refrigerant and its pressure/safety class.
  • Never intentionally vent refrigerant. Recover and manage refrigerant in accordance with applicable federal, state and local rules.

EPA Purchase Verification

Purchaser requirement: EPA Section 608 certification or qualifying employer/resale documentation; A2L training/procedures.

Before fulfillment, Cool Gas Depot must verify the applicable technician certification, employer authorization or resale documentation and retain the required online-sales records. Orders may be placed on hold or cancelled when acceptable documentation is not provided.

Hazardous-Material Shipping

This product is a regulated refrigerant/compressed gas and cannot be shipped as an ordinary parcel. Availability, destination eligibility, carrier acceptance, approved packaging and any required hazardous-material fees must be confirmed before fulfillment. Delivery dates are estimates until the order passes compliance and carrier review.

Shipping, Returns and Cancellations

  • Shipping area: United States destinations permitted by the carrier and applicable regulations.
  • Shipping charge: Free standard shipping on eligible orders.
  • Processing: Normally 1–2 business days after payment, inventory and purchaser-documentation review.
  • Estimated delivery: Normally 3–7 business days after dispatch. Hazardous-material routing, weather, remote destinations and carrier controls may extend delivery.
  • Returns: Contact Cool Gas Depot within 30 days. Only unopened, unused and factory-sealed cylinders are eligible, subject to authorization and carrier/hazardous-material restrictions. Approved return shipping is provided at no cost. Never send a refrigerant cylinder back without written instructions.
  • Cancellations: An order may be cancelled before shipment. After carrier acceptance, the approved return process applies.

Review our Shipping Policy and Returns & Refund Policy before ordering.

Safety Data Sheet and Documentation

This listing is for Opteon™ XL41 (R-454B) refrigerant manufactured by The Chemours Company. The current Safety Data Sheet must match the exact product and cylinder label supplied with the order. Cool Gas Depot does not substitute an SDS from another brand or manufacturer. To request the current SDS before shipment, email support@coolgasdepot.shop and include SKU CGD-R454B-22.

Also review our Refrigerant Safety Information and EPA Requirements & Refrigerant Purchase Policy.

Before You Order

  1. Read the equipment or vehicle label and confirm the exact refrigerant type.
  2. Confirm the required net quantity, cylinder connection and service-equipment compatibility.
  3. Review the current Safety Data Sheet and the equipment manufacturer’s service instructions.
  4. Verify that purchase, possession, installation and use are permitted at the delivery location.
  5. Arrange installation or service by a properly trained and certified technician.

Important Notice

Refrigerants are not universally interchangeable. Never select a refrigerant only because operating pressures or applications appear similar. Incorrect refrigerant, mixed refrigerant, improper charging or incompatible lubricant can damage equipment, reduce performance and create serious safety hazards. Packaging artwork may change over time, but the supplied product must match the Opteon brand, refrigerant specification, manufacturer, and package size identified in this listing. Always rely on the cylinder label and Safety Data Sheet supplied with the product.

Additional information

Refrigerant Type

R454B

Net Contents

20 lb (9.1 kg)

Main Application

New HVAC and heat-pump systems specifically designed for R-454B

Safety Classification

A2L – mildly flammable

Manufacturer Part Number

D15444398

Trustpilot reviews

★★★★★
5 stars

“Found this store after searching for hours. They had a product that was sold out everywhere else, and the price was unbeatable. Fast shipping and excellent packaging too!”

Harry
★★★★★
5 stars

“I almost didn't order because I couldn't find this product anywhere, but I'm glad I did. Amazing value for the money and excellent customer service when I had a question.”

John
★★★★★
5 stars

“I was honestly skeptical because I'd never heard of this website before, but everything went smoothly. The product arrived exactly as described, and the price was much lower than anywhere else I checked. I'll definitely order again.”

Leo
★★★★★
5 stars

“I'm so glad I found this clearance sale! The product matched the description, the customer support was responsive, and the price was unbeatable.”

Jack
★★★★★
5 stars

“Unbeatable discounts! I paid much less than I would have on other websites. I highly recommend this store.”

Tom
★★★★★
5 stars

“I took advantage of the clearance sale, and I still can't believe the incredible prices! The product is flawless, and the delivery was fast. I'm extremely satisfied with my purchase.”

Marcus
★★★★★
5 stars

“This has become one of my favorite online stores. They carry products that are hard to find and the prices are much better than the big retailers. Very satisfied with my purchase.”

Ethan